Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
2.
Arq. bras. oftalmol ; 83(3): 215-224, May-June 2020. tab, graf
Article in English | LILACS | ID: biblio-1131588

ABSTRACT

ABSTRACT Purpose: Our initial goal was to compare the efficacy and safety of a glaucoma drainage device and trabeculectomy for children with primary congenital glaucoma after angular surgery failure. However, we discontinued the study due to the rate of complications and wrote this report to describe the results obtained with the two techniques in this particular group. Methods: This was a parallel, non-masked, controlled trial that included patients aged 0-13 years who had undergone previous trabeculotomy or goniotomy and presented inadequately controlled glaucoma with an intraocular pressure ≥21 mmHg on maximum tolerated medical therapy. We randomized the patients to undergo either placement of a 250-mm2 Baerveldt glaucoma implant or mitomycin-augmented trabeculectomy. The main outcome measure was intraocular pressure control. We calculated complete success (without hypotensive ocular medication) and qualified success (with medication) rates. We defined failure as uncontrolled intraocular pressure, presence of serious complications, abnormal increase in ocular dimensions, or confirmed visual acuity decrease. Results: We studied 13 eyes of 13 children (five in the glaucoma drainage device group; eight in the trabeculectomy group). Both surgical procedures produced a significant intraocular pressure reduction 12 months after intervention from the baseline (tube group, 22.8 ± 5.9 mmHg to 12.20 ± 4.14 mmHg, p=0.0113; trabeculectomy group, 23.7 ± 7.3 mmHg to 15.6 ± 5.9 mmHg, p=0.0297). None of the patients in the tube group and 37.5% of those in the trabeculectomy group achieved complete success in intraocular pressure control after 12 months of follow-up (p=0.928, Chi-square test). Two patients (40%) had serious complications at the time of tube aperture (implant extrusion, retinal detachment). Conclusions: Both the tube and trabeculectomy groups presented similar intraocular pressure controls, but complete success was more frequent in the trabeculectomy group. Non-valved glaucoma drainage devices caused potentially blinding complications during tube opening. Because of the small sample size, we could not draw conclusions as to the safety data of the studied technique.


RESUMO Objetivo: O objetivo inicial era comparar a eficácia e a segurança do implante de drenagem e a trabeculectomia em crianças com glaucoma congênito primário após falência de cirurgia angular. Como o estudo foi descontinuado devido à taxa de complicações, o objetivo deste artigo foi descrever os resultados das duas técnicas neste grupo específico. Métodos: Ensaio clínico randomizado, não mascarado, incluindo pacientes com idade de 0 a 13 anos previamente submetidos à goniotomia ou trabeculotomia. Os pacientes, que apresentavam glaucoma não controlado com pressão intraocular ≥21 mmHg em terapia medicamentosa máxima, foram randomizados para o implante de drenagem de Baerveldt 250 mm2 (Grupo Tubo) ou trabeculectomia com mitomicina (grupo TREC). O principal desfecho avaliado foi o controle da pressão intraocular. Sucesso completo (sem medicação ocular hipotensora) e sucesso qualificado (com medicação) foram descritos. A falência foi baseada na pressão intraocular não controlada, presença de complicações sérias, aumento anormal das dimensões oculares e diminuição confirmada da acuidade visual. Resultados: Treze olhos de 13 crianças foram estudados (cinco no grupo Tubo e oito no grupo TREC). Ambos os procedimentos reduziram a pressão intraocular em relação às medidas iniciais após 12 meses da intervenção (grupo Tubo 22.8 ± 5.9 mmHg para 12.20 ± 4.14 mmHg, p=0.0113; grupo TREC, 23.7 ± 7.3 mmHg para 15.6 ± 5.9 mmHg, p=0.0297). Nenhum paciente no grupo Tubo e 37.5% do grupo TREC alcançaram o sucesso completo após 12 meses de acompanhamento (p=0.928, teste qui-quadrado). Dois pacientes (40%) apresentaram sérias complicações no momento da abertura do tubo (extrusão do implante e descolamento de retina). Conclusão: Os dois grupos estudados apresentaram resultados semelhantes quanto ao controle da pressão intraocular, mas o sucesso completo foi mais frequente no grupo da trabeculectomia. Implantes de drenagem não valvulados podem cursar com potenciais complicações visuais no momento da abertura do tubo. Devido ao pequeno tamanho da amostra, não foi possível determinar quaisquer dados de segurança conclusivos em relação à técnica estudada.


Subject(s)
Humans , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , Trabeculectomy , Glaucoma , Glaucoma Drainage Implants , Postoperative Complications , Visual Acuity , Glaucoma/surgery , Follow-Up Studies , Treatment Outcome , Mitomycin , Intraocular Pressure
4.
Arq. bras. oftalmol ; 77(1): 50-53, Jan-Feb/2014. graf
Article in English | LILACS | ID: lil-715555

ABSTRACT

Cyclodialysis is a relatively rare condition usually caused by ocular injury; however, it can also be caused iatrogenically during intraocular surgery. Hypotony maculopathy is the most important complication and the primary reason for visual loss. Clinical diagnosis using gonioscopy may be difficult, and ultrasound biomicroscopy (UBM) can be an alternative. There are different kinds of treatments, and the optimal one remains controversial. Here we describe a case of traumatic cyclodialysis with persistent ocular hypotony treated by direct cyclopexy, as illustrated by UBM performed before and after surgery.


Ciclodiálise é uma condição relativamente rara, geralmente devido a um trauma ocular, mas também pode ser causada iatrogenicamente como consequência de cirurgia intraocular. A maculopatia hipotônica é a complicação mais importante e a principal razão para a perda visual nessa situação. O diagnóstico clínico por gonioscopia pode ser difícil e a biomicroscopia ultrassônica (UBM) pode ser uma alternativa. Existem diferentes tipos de tratamentos e algumas controvérsias sobre a melhor opção. Neste relato, nós descrevemos um caso de ciclodiálise traumática com hipotonia ocular persistente tratado por cyclopexia direta avaliado por UBM antes e depois da cirurgia.


Subject(s)
Adult , Humans , Male , Ciliary Body/injuries , Ciliary Body/surgery , Eye Injuries/surgery , Ocular Hypotension/surgery , Ciliary Body , Eye Injuries , Gonioscopy , Microscopy, Acoustic , Ophthalmologic Surgical Procedures , Ocular Hypotension
5.
Arq. bras. oftalmol ; 76(2): 85-89, mar.-abr. 2013. ilus, tab
Article in English | LILACS | ID: lil-678172

ABSTRACT

BACKGROUND: Visual processing deficits have been reported for patients with schizophrenia. Previous studies demonstrated differences in early-stage processing of schizophrenics, although the nature, extent, and localization of the disturbance are unknown. The magnocellular and parvocellular visual pathways are associated with transient and sustained channels, but their respective contributions to schizophrenia-related visual deficits remains controversial. PURPOSE: The aim of this study was to evaluate magnocellular dysfunction in schizophrenia using frequency doubling technology. METHODS: Thirty-one patients with schizophrenia and 34 healthy volunteers were examined. Frequency doubling technology testing was performed in one session, consisting of a 15-minute screening strategy followed by the C-20 program for frequency doubling technology. RESULTS: Schizophrenic patients showed lower global mean sensitivity (30,97 ± 2,25 dB) compared with controls (32,17 ± 3,08 dB), p<0.009. Although there was no difference in the delta sensitivity of hemispheres, there was a difference in sensitivity analysis of the fibers crossing the optic chiasm, with lower mean sensitivity in the patient group (28,80 dB) versus controls (30,66 dB). The difference was higher in fibers that do not cross the optic chiasm, with lower mean sensitivity in patients (27,61 dB) versus controls (30,26 dB), p<0.005. CONCLUSIONS: Our results suggest that there are differences between global sensitivity and fiber sensitivity measured by frequency doubling technology. The different sensitivity of fibers that do not cross the optic chiasm is consistent with most current etiological hypotheses for schizophrenia. The decreased sensitivity responses in the optic radiations may significantly contribute to research assessing early-stage visual processing deficits for patients with schizophrenia.


HISTÓRICO: Déficits de processamento visual foram relatados em pacientes com esquizofrenia. Estudos anteriores demonstraram diferenças no estágio inicial de processamento de esquizofrênicos, embora a natureza, extensão e localização do distúrbio são desconhecidas. As vias magnocelulares e parvocelular visuais são associados com canais transitórios e sustentado, mas suas respectivas contribuições para a esquizofrenia relacionados com déficits visuais permanece controverso. OBJETIVO: Avaliar a disfunção magnocelular na esquizofrenia usando a tecnologia de frequência dupla. MÉTODOS: Trinta e um pacientes com esquizofrenia e 34 voluntários saudáveis ​​foram examinados. Tecnologia de frequência dupla foi realizada em uma sessão, consistindo de uma estratégia de rastreio de 15 minutos, seguido do programa de C-20 para tecnologia de frequência dupla. RESULTADOS: Os pacientes esquizofrênicos apresentaram sensibilidade média inferior global (30,97 ± 2,25 dB), em comparação com os controles (32,17 ± 3,08 dB), p<0,009. Embora não tenha ocorrido diferença na sensibilidade do delta de hemisférios, houve uma diferença na análise de sensibilidade das fibras que atravessam a quiasma, com menor sensibilidade média no grupo de pacientes (28,80 dB) versus controlos (30,66 dB). A diferença foi maior em fibras que não cruzam o quiasma óptico, com menor sensibilidade média em pacientes (27,61 dB) versus controles (30,26 dB), p<0,005. CONCLUSÕES: Nossos resultados sugerem que há diferenças entre a sensibilidade global e sensibilidade da fibra medida pela tecnologia de frequência dupla. A sensibilidade diferente de fibras que não cruzam o quiasma óptico é compatível com a maioria das atuais hipóteses etiológicas para a esquizofrenia. As respostas diminuição da sensibilidade nas radiações ópticas podem contribuir significativamente para pesquisar a avaliação em estágio inicial déficits de processamento visual em pacientes com esquizofrenia.


Subject(s)
Adult , Female , Humans , Male , Geniculate Bodies/physiopathology , Schizophrenia/physiopathology , Visual Field Tests/methods , Visual Pathways/physiopathology , Visual Perception/physiology , Case-Control Studies , Contrast Sensitivity/physiology , Schizophrenia/complications
6.
Arq. bras. oftalmol ; 74(6): 410-413, nov.-dez. 2011. tab
Article in English | LILACS | ID: lil-613439

ABSTRACT

PURPOSE: To analyze the correlation between quantitative measurements outcomes and keratoconus patients' vision related quality of life (v-QoL) following intrastromal corneal ring segment implantation. METHODS: The NEI-RQL (National Eye Institute Refractive Error Quality of Life) was administered to patients requiring intrastromal corneal ring segment implantation, before and after surgery, wearing best correction for 40 days minimum. Visual acuity, refraction, corneal topography, aberrometry data (VOL-CT. software) and contrast sensitivity were recorded before and 3 months after surgery. The main outcome measures were best corrected visual acuity, refraction, steep keratometric value (Kmax), aberrometry, contrast sensitivity and v-QoL. RESULTS: There were 42 keratoconic patients (69 eyes): 19 male and 23 female, mean age 24.9 ± 5 years in this prospective study. Binocular best corrected visual acuity improved (0.13 ± 0.03 before to -0.01 ± 0.01 logMAR after surgery, p<0.001). There was a statistically significant improvement in mean spherical refraction (2.81 ± 0.44 to 1.71 ± 0.31), cylinder component (3.89 ± 0.22 to 1.82 ± 0.21), spherical equivalent (4.55 ± 0.46 to 2.40 ± 0.30), Kmax (55.92 D ± 0.62 to 52.16 D ± 0.58 D) and root mean square low order (p<0.001). Contrast sensitivity (CS) improved at all spatial frequencies: at 6 cpd improvement was higher. Root mean square higher order did not improved p=0.422. There was significant improvement across all NEI-RQL scales after surgery. Multivariate analysis showed that gender (males more satisfied than females), cylinder (1 D reduction improves 5 points in general NEI-RQL scores) and normal contrast sensitivity at 3 and 6 cpd were correlated with v-QoL. Other variables such as best corrected visual acuity, root mean square low order, root mean square higher order and Kmax did not show influence on NEI-RQL scores. CONCLUSIONS: The best patient response predictors with the NEI-RQL instrument were gender, normal CS at 3 and 6 cpd and cylinder reduction. The use of this questionnaire was crucial to assess the influence of optical tests on v-QoL in keratoconus patients who were referred for intrastromal corneal ring segment implantation.


OBJETIVO: Analisar a correlação entre fatores relacionados aos pacientes com ceratocone e suas medidas quantitativas e os resultados da qualidade de vida com o implante do anel intraestromal (ICRS). MÉTODOS: O questionário de qualidade de vida relacionado a visão (QdV-v) NEI-RQL (National Eye Institute Refractive Error Quality of Life) validado na língua portuguesa foi administrado a pacientes com indicação de implante do anel intraestromal antes e depois da cirurgia quando eles já estavam usando a correção por pelo menos 40 dias. Acuidade visual com a melhor correção, topografia de córnea, aberrometria e sensibilidade ao contraste foram medidos antes e três meses após a cirurgia. RESULTADOS: Foram incluídos neste estudo prospectivo 42 pacientes (69 olhos): 19 homens e 23 mulheres com idade média de 24,9 ± 5 anos. Houve melhora estatisticamente significante na acuidade visual com a melhor correção binocular (0,13 ± 0,03 antes para -0,01 ± 0,01 logMAR após a cirurgia, p<0,001), na refração esférica média (2,81 ± 0,44 para 1,71 ± 0,31), no componente cilíndrico (3,89 ± 0,22 para 1,82 ± 0,21), no equivalente esférico (4,55 ± 0,46 para 2,40 ± 0,30), na ceratometria máxima (55,92 D ± 0,62 para 52,16 D ± 0,58 D) e no RMS (root mean square) de baixa ordem (p<0,001). O RMS de alta ordem não teve melhora significante p=0,422. A sensibilidade ao contraste (SC) melhorou significativamente em todas as frequências especialmente na de 6 cpg. Houve melhora significante em todas as escalas do NEI-RQL após a cirurgia. A análise multivariada mostrou que sexo (homens com melhores índices de QdV-v que as mulheres), cilindro (1 D de redução aumenta em 5 pontos a escala geral do NEI-RQL) e SC normal nas frequências de 3 e 6 cpg são os fatores que interferem nos escores de QdV-v dos pacientes com implante de anel intraestromal. As outras variáveis como acuidade visual com a melhor correção, aberrometria e ceratometria máxima não influenciaram nos escores do NEI-RQL. CONCLUSÕES: Os fatores que se correlacionam a melhores pontuações na QdV-v dos pacientes com implante de anel intraestromal são: sexo, SC normal nas frequências de 3 e 6 cpg e diminuição do cilindro. A análise das medidas objetivas em conjunto com o NEI-RQL foi fundamental para identificar os fatores que influenciam nos resultados subjetivos dos pacientes com ceratocone e implante de anel intraestromal.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Young Adult , Keratoconus/surgery , Prostheses and Implants , Quality of Life , Age Factors , Contrast Sensitivity , Corneal Topography , Educational Status , Prospective Studies , Prosthesis Implantation/methods , Sex Factors , Surveys and Questionnaires , Treatment Outcome , Visual Acuity
7.
Arq. bras. oftalmol ; 74(5): 326-329, set.-out. 2011. ilus, tab
Article in English | LILACS | ID: lil-608402

ABSTRACT

Purpose: To evaluate the ophthalmic artery hemodynamics in patients with chronic heart failure. Methods: Doppler parameters of ophthalmic artery of 18 patients with chronic heart failure in different stages of the disease were compared with 21 healthy volunteers (control group). These parameters were also correlated with echocardiographic assessments and clinical cardiologic status. Results: Mean diastolic velocity was 5.14 ± 2.4 cm/s in the chronic heart failure group and 7.44 ± 3.5 cm/s in the control group (p=0.007). Mean resistance index of the ophthalmic artery was 0.76 ± 0.08 in the chronic heart failure group and 0.70 ± 0.08 in the control group (p=0.04). Mean systolic velocity of the ophthalmic artery was 22.03 ± 7.7 cm/s in the chronic heart failure group and 25.32 ± 9.2 cm/s in the control group (p=0.24). There was a negative correlation between the resistance index of the ophthalmic artery and systemic blood pressure of patients with chronic heart failure (r= -0.47, p=0.007). Diastolic velocity of the ophthalmic artery correlated positively with systemic blood pressure (r=0.44, p=0.02). Conclusion: Lower diastolic velocity and higher resistance index were observed in the ophthalmic artery of chronic heart failure patients when compared to the control group, which probably reflects the presence of orbital vasoconstriction in response to low cardiac output. Therefore, the influence of these findings on the structure and function of the optic nerve head deserves investigation.


Objetivo: Avaliar o fluxo sanguíneo da artéria oftálmica em pacientes com insuficiência cardíaca crônica. Métodos: Parâmetros da ultrassonografia Doppler em cores da artéria oftálmica de 18 pacientes com insuficiência cardíaca crônica em diferentes estágios da doença foram comparados com 21 voluntários saudáveis (grupo controle). Estes parâmetros foram também correlacionados com avaliação ecocardiográfica e quadro clínico cardiológico. Resultados: A média da velocidade diastólica foi 5,14 ± 2,4 cm/s no grupo insuficiência cardíaca crônica e 7,44 ± 3,5 cm/s no grupo controle (p=0,007). O índice de resistência da artéria oftálmica foi de 0,76 ± 0,08 no grupo insuficiência cardíaca crônica e 0,70 ± 0,08 no grupo controle (p=0,04). A média de velocidade sistólica da artéria oftálmica foi 22,03 ± 7,7 cm/s no grupo insuficiência cardíaca crônica e 25,32 ± 9,2 cm/s no grupo controle (p=0,24). A pressão arterial sistêmica dos pacientes com insuficiência cardíaca crônica correlacionou-se negativamente com o índice de resistência da artéria oftálmica (r= -0,47, p=0,007) e positivamente com a velocidade diastólica da artéria oftálmica (r=0,44, p=0,02). Conclusão: Velocidade diastólica mais baixa e índice de resistência mais alto foram observados na artéria oftálmica de pacientes com insuficiência cardíaca crônica quando comparados ao grupo controle, o que provavelmente reflete a presença de vasoconstrição orbital em resposta ao baixo débito cardíaco. Portanto, a influência desses achados sobre a estrutura e função da cabeça do nervo óptico merece ser investigada.


Subject(s)
Female , Humans , Male , Middle Aged , Heart Failure/physiopathology , Ophthalmic Artery , Blood Flow Velocity/physiology , Case-Control Studies , Chronic Disease , Cross-Sectional Studies , Ophthalmic Artery/physiopathology , Severity of Illness Index , Ultrasonography, Doppler, Color , Vascular Resistance/physiology
8.
Arq. bras. oftalmol ; 74(2): 106-109, Mar.-Apr. 2011. ilus, tab
Article in English | LILACS | ID: lil-593131

ABSTRACT

AIM: To evaluate the intraocular pressure and ocular perfusion pressure during a hemodialysis. METHODS: Sixty-seven eyes from thirty-five patients were evaluated at the beggining of hemodialysis, 2 hours and 4 hours after initiation. Intraocular pressure was evaluated using a Tonopen. Systolic and diastolic arterial pressures were measured with a manual sphygmomanometer. The ocular perfusion pressure was estimated by mea suring the difference between 2/3 of the mean arterial pressure and the intraocular pressure values. Generalized estimating equations were used to evaluate the difference between the repeated measurements using the appropriate correction for inter-eye dependency. RESULTS: There was no statistically significant difference in ocular perfusion pressure, in intraocular pressure (p=0.93) and in systolic arterial pressure (p=0.92) at the three time points (p=0.69). But, when analyzing the extreme values, some patients exhibited lower diastolic perfusion pressures at all time points. CONCLUSION: Our results did not support the view that significant changes in ocular perfusion pressure and intraocular pressure occur during hemodialysis session. However, we observed that some patients exhibited lower diastolic perfusion pressures, which could be a poor prognostic factor for glaucoma patients.


OBJETIVO: Avaliar a pressão intraocular e a pressão de perfusão ocular durante uma sessão de hemodiálise. MÉTODOS: Sessenta e sete olhos de trinta e cinco pacientes foram avaliados no início, após 2 horas e após 4 horas do início de uma sessão de hemodiálise. A pressão intraocular foi avaliada usando o aparelho Tonopen. Pressões arteriais sistólica e diastólica foram aferidas usando esfigmomanômetro manual. A pressão de perfusão ocular foi estimada por meio do cálculo da diferença entre 2/3 da pressão arterial média e valores da pressão intraocular. Equações de estimação generalizada foram usadas para avaliar a diferença entre medidas repetidas usando correção apropriada para dependência entres olhos. RESULTADOS: Não houve diferença estatisticamente significativa na pressão de perfusão ocular, PIO (p=0,93) e na pressão arterial sistólica (p=0,92) nos três períodos medidos da hemodiálise (p=0,69). Mas, quando analisados valores extremos, alguns pacientes exibiram pressões diastólicas menores em todos os períodos aferidos. CONCLUSÃO: Nossos resultados não apontaram mudanças significativas na pressão de perfusão ocular e pressão intraocular durante a hemodiálise. No entanto, foi observado que alguns pacientes exibiram pressões diastólicas menores, o que pode ser um fator de prognóstico ruim para pacientes com glaucoma.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Eye/blood supply , Intraocular Pressure/physiology , Renal Dialysis , Analysis of Variance , Blood Pressure/physiology , Glaucoma/physiopathology , Risk Factors , Time Factors
9.
Arq. bras. oftalmol ; 73(6): 497-500, nov.-dez. 2010. tab
Article in English | LILACS | ID: lil-572211

ABSTRACT

Purpose: To compare the performance of gonioscopy and noncontact morphometry with anterior chamber tomography (High Resolution Pentacam - HR) using optical Scheimpflug images in the evaluation of the anterior chamber angle (ACA). Methods: Transversal study. 112 eyes from 74 subjects evaluated at the Glaucoma Department, Fluminense Federal University, underwent gonioscopy and Pentacam HR. Using gonioscopy, the ACA was graded using the Shaffer Classification (SC) by a single experienced examiner masked to the Pentacam HR findings. Narrow angle was determined in eyes in which the posterior trabecular meshwork could not be seen in two or more quadrants on non-indentation gonioscopy (SC Grade 2 or less). Pentacam HR images of the nasal and temporal quadrants were evaluated by custom software to automatically obtain anterior chamber measurements, such as: anterior chamber angle (ACA), anterior chamber volume (ACV) and anterior chamber depth (ACD). Results: Based on gonioscopy results, 74 (60.07 percent) eyes of patients classified as open-angle (SC 3 and 4) and 38 (33.93 percent) eyes of patients classified as narrow-angle (SC 1 and 2). Noncontact morphometry with Scheimpflug images revealed a mean ACA of 39.20 ± 5.31 degrees for open-angle and 21.18 ± 7.98 degrees for narrow-angle. The open-angle group showed significant greater ACV and ACD values when compared to narrow-angle group (ACV of 193 ± 36 mm³ vs. 90 ± 25 mm³, respectively, p<0.001; and ACD of 3,09 ± 0,42 mm vs. 1,55 ± 0,64 mm, respectively, p<0.0001.). In screening eyes with open-angle and narrow-angle with the Pentacam ACA of 20º (SC Grade 2) using the ROC curves, the analysis showed 52.6 percent of sensitivity and 100 percent of specificity. Conclusions: The Pentacam showed ability in detecting eyes at risk for angle closure analyzing ACV and ACD.


Objetivo: Comparar os resultados da gonioscopia com as medidas morfométricas do segmento anterior obtidas pela tomografia (Pentacam High Resolution - HR), utilizando imagens ópticas de Scheimpflug na avaliação do ângulo da câmara anterior (ACA). Métodos: Realizado estudo transversal com avaliação de 112 olhos de 74 pacientes avaliados no Setor de Glaucoma da Universidade Federal Fluminense, submetidos ao exame da gonioscopia e do Pentacam HR. Na gonioscopia o ACA foi classificado utilizando a Classificação de Shaffer (SC), realizado por um único examinador experiente, e seus resultados foram comparados às medidas do Pentacam HR. Ângulos estreitos foram classificados nos olhos em que a malha posterior trabecular não foi observada em dois ou mais quadrantes na gonioscopia tradicional (SC Grau 2 ou menor). As imagens dos quadrantes nasal e temporal obtidas pelo Pentacam HR foram avaliadas por um software personalizado que obtêm automaticamente as seguintes medidas da câmara anterior: ângulo da câmara anterior (ACA), volume da câmara anterior (ACV) e profundidade da câmara anterior (ACD). Resultados: Com base nos resultados gonioscopia, 74 (60,07 por cento) olhos foram classificados como ângulo aberto (SC 3 e 4) e 38 (33,93 por cento) olhos foram classificados como ângulo estreito (SC 1 e 2). A morfometria de não contato com as imagens Scheimpflug revelou uma média de ACA 39,20 ± 5,31 graus nos ângulos abertos e 21,18 ± 7,98 graus nos ângulos estreitos. O grupo classificado como ângulo aberto mostrou medidas significativamente maiores de ACV e ACD quando comparado ao grupo de ângulo estreito (ACV de 193 ± 36 mm³ vs 90 ± 25 mm³, respectivamente, p <0,001 e ACD de 3,09 ± 0,42 mm vs 1,55 ± 0,64 mm, respectivamente, p<0,0001). Na diferenciação dos olhos com ângulo aberto e olhos com ângulo estreito no Pentacam, a análise das curvas ROC demonstraram que na medida de 20º (SC Grau 2) resultaram em 52,6 por cento de sensibilidade em 100 por cento de especificidade. Conclusões: O Pentacam HR mostrou habilidade em detectar os olhos com risco de fechamento angular na analise do ACV e do ACD.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Anterior Chamber/pathology , Glaucoma, Angle-Closure/pathology , Gonioscopy/methods , Anterior Chamber , Cross-Sectional Studies , Glaucoma, Angle-Closure , Gonioscopy/classification , Image Processing, Computer-Assisted , ROC Curve
10.
Arq. bras. oftalmol ; 73(4): 320-322, July-Aug. 2010. ilus
Article in English | LILACS | ID: lil-560602

ABSTRACT

PURPOSE: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. RESULTS: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). CONCLUSION: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.


OBJETIVO: Avaliar e comparar a habilidade de observadores em medir a razão escavação/disco (CDR) por meio de figuras esquemáticas. MÉTODOS: Em um estudo prospectivo, randomizado e mascarado, 43 imagens representado CDR horizontais e verticais entre 0,2 e 0,9 foram desenvolvidas e apresentadas em uma tela de computador para 171 participantes. RESULTADOS: Para todos os intervalos de CDR a concordância foi satisfatória para análise kappa (0,755 e 0,730 para CDR horizontais e verticais, respectivamente) e para concordância de Lin (R=0,88 e R=0,86 para medidas horizontais e verticais respectivamente). No entanto, a concordância foi fraca para valores intermediários de CDR. A pior concordância ocorreu para CDR horizontais e verticais entre 0,4 e 0,6. CONCLUSÃO: Apesar da boa concordância geral entre as respostas corretas e as respostas dadas pelos participantes, a concordância absoluta para valores intermediários de CDR mostrou-se muito fraca tanto para figuras horizontais como verticais.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Diagnostic Techniques, Ophthalmological/instrumentation , Glaucoma/classification , Optic Disk/anatomy & histology , Optic Nerve Diseases/diagnosis , Brazil , Cross-Sectional Studies , Glaucoma/diagnosis , Observer Variation , Ophthalmology/instrumentation , Photography , Reproducibility of Results , Sensitivity and Specificity
11.
Arq. bras. oftalmol ; 73(4): 354-357, July-Aug. 2010. ilus, tab
Article in English | LILACS | ID: lil-560610

ABSTRACT

PURPOSE: To determine factors associated with the test-retest variability of optic nerve head (ONH) topography measurements with confocal scanning laser ophthalmoscopy (CSLO) in newly diagnosed glaucomatous patients. METHODS: Consecutive patients with newly diagnosed primary open-angle glaucoma were prospectively enrolled. Patients presenting with any ocular disease other than glaucoma were excluded. All patients underwent CSLO using the Heidelberg Retina Tomograph III (HRT-III) in one randomly selected eye (three consecutive scans; performed by the same examiner). For each Heidelberg Retina Tomograph III parameter, repeatability was assessed using within subject standard deviation (Sw) and coefficient of variation (CVw), repeatability coefficient (RC) and intraclass correlation coefficient (ICC). Scatter plots and regression lines were constructed to identify which factors influenced test-retest measurement variability. RESULTS: A total of 32 patients were included (mean age, 65.4 ± 13.8 years). Most patients were female (65 percent) and white (50 percent). Among all Heidelberg Retina Tomograph III parameters evaluated, rim area and mean cup depth had the best measurement repeatability. Vertical cup-to-disc ratio (CDR, as determined by optic disc stereophotograph examination) was significantly associated (R²=0.21, p<0.01) with test-retest measurement variability. Eyes with larger CDR showed less variable measurements. Other factors, including age, disc area, central corneal thickness and intraocular pressure were not significant (p>0.14). CONCLUSION: Heidelberg Retina Tomograph III showed good test-retest repeatability for all ONH topographic measurements, mainly for rim area and mean cup depth. Test-retest repeatability seemed to improve with increasing CDR. These findings suggest that HRT-III topographic measurements should be cautiously interpreted when evaluating longitudinally glaucoma patients with early structural damage (small CDR).


OBJETIVO: Determinar os fatores associados à variabilidade (teste-reteste) das medidas topográficas da cabeça do nervo óptico (CNO) utilizando a oftalmoscopia confocal de varredura a laser (CSLO) em pacientes com glaucoma recém-diagnosticados. MÉTODOS: Neste estudo, pacientes com glaucoma primário de ângulo aberto recém-diagnosticados foram prospectivamente incluídos. Aqueles que apresentassem outras doenças oculares (exceto glaucoma) foram excluídos. Todos os pacientes incluídos no estudo foram submetidos à CSLO usando o aparelho Heidelberg Retina Tomograph III (HRT-III) em um olho aleatoriamente selecionado (três exames consecutivos realizados pelo mesmo examinador). Para cada parâmetro do Heidelberg Retina Tomograph III, a repetibilidade foi avaliada através dos seguintes indicadores: desvio padrão (DP) e coeficiente de variação (CV) individual, coeficiente de repetibilidade (CR) e coeficiente de correlação intraclasse (CCI). Diagramas de dispersão e linhas de regressão foram construídos para identificar quais fatores poderiam influenciar a variabilidade das medidas. RESULTADOS: Trinta e dois pacientes foram incluídos no estudo (idade média, 65,4 ± 13,8 anos). A maior parte era composta por mulheres (65 por cento) e pacientes brancos (50 por cento). Dentre os parâmetros de Heidelberg Retina Tomograph III avaliados, a área da rima e a profundidade média da escavação apresentaram os melhores valores de repetibilidade. A relação escavação/disco (E/D) vertical (baseada na análise de estereofotografia do disco óptico), foi significativamente associada (R²=0.21, p<0.01) com a variabilidade teste-reteste. Pacientes com relação E/D maiores apresentaram medidas menos variáveis. Outros fatores como idade, área do disco, espessura corneana central e pressão intraocular não foram significativas (p>0,14). CONCLUSÃO: O Heidelberg Retina Tomograph III mostrou boa repetibilidade (teste-reteste) para todos os parâmetros topográficos da CNO avaliados, principalmente em relação à área da rima e à profundidade média da escavação. A repetibilidade teste-reteste apresentou melhores resultados com o aumento da relação E/D. Esses achados sugerem que as medidas topográficas do Heidelberg Retina Tomograph III devem ser interpretadas com cautela quando avaliarmos longitudinalmente pacientes glaucomatosos com dano estrutural inicial (relação E/D menor).


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Glaucoma, Open-Angle/diagnosis , Ophthalmoscopy/methods , Optic Disk/anatomy & histology , Tomography/methods , Age Factors , Cross-Sectional Studies , Microscopy, Confocal , Ophthalmoscopes/standards , Optic Nerve Diseases/diagnosis , Reproducibility of Results , Sex Factors
12.
Rev. bras. ecocardiogr. imagem cardiovasc ; 22(3): 35-38, jul.-set. 2009. tab
Article in Portuguese | LILACS | ID: lil-522523

ABSTRACT

Os autores fazem a revisão do emprego da atropina, durante a realização do ecocardiograma de estresse farmacológico, os riscos de glaucoma agudo e o tratamento inicial do glaucoma agudo por bloqueio pupilar, caso a assistênia oftalmológica não possa ser realizada de pronto. Embora seja complicação rara durante a realização da ecocardiografia de estresse farmacológica, o glaucoma agudo deve ser prontamente reconhecido pelo ecocardiografista e as terapêuticas iniciais devem ser instituídas rapidamente.


Subject(s)
Humans , Atropine , Echocardiography, Stress/methods , Echocardiography, Stress , Glaucoma/complications , Glaucoma/diagnosis , Risk Factors
13.
Arq. bras. oftalmol ; 72(2): 139-145, mar.-abr. 2009. ilus, tab
Article in English | LILACS | ID: lil-513906

ABSTRACT

PURPOSE: The ability to predict and understand which biomechanical properties of the cornea are responsible for the stability or progression of keratoconus may be an important clinical and surgical tool for the eye-care professional. We have developed a finite element model of the cornea, that tries to predicts keratoconus-like behavior and its evolution based on material properties of the corneal tissue. METHODS: Corneal material properties were modeled using bibliographic data and corneal topography was based on literature values from a schematic eye model. Commercial software was used to simulate mechanical and surface properties when the cornea was subject to different local parameters, such as elasticity. RESULTS: The simulation has shown that, depending on the corneal initial surface shape, changes in local material properties and also different intraocular pressures values induce a localized protuberance and increase in curvature when compared to the remaining portion of the cornea. CONCLUSIONS: This technique provides a quantitative and accurate approach to the problem of understanding the biomechanical nature of keratoconus. The implemented model has shown that changes in local material properties of the cornea and intraocular pressure are intrinsically related to keratoconus pathology and its shape/curvature.


OBJETIVOS: A possibilidade de prever e entender quais propriedades biomecânicas da córnea podem ser responsáveis pelo progresso ou estabilização do ceratocone pode ser uma importante ferramenta clínica e cirúrgica para o oftalmologista. Neste trabalho foi desenvolvido um modelo em elementos finitos da córnea, o qual prevê o surgimento de deformações semelhantes ao ceratocone e sua evolução baseado em propriedades biomecânicas do tecido corneano. MÉTODOS: As propriedades biomecânicas da córnea foram modeladas segundo dados disponíveis na literatura para olhos esquemáticos. Softwares comerciais foram usados para simular propriedades de superfície e material quando a córnea foi submetida a diferentes parâmetros locais de elasticidade. RESULTADOS: As simulações conduzidas aqui mostraram que, dependendo do formato inicial da córnea, mudanças nas propriedades locais do material para diferentes pressões intraoculares, induzem uma protuberância localizada e um aumento significativo de curvatura quando comparado ao restante da córnea. CONCLUSÕES: A técnica apresentada aqui permite o estudo mais preciso e quantitativo da natureza biomecânica do ceratocone. O modelo implementado demonstrou que mudanças locais de propriedades biomecânicas relacionais à elasticidade para uma mesma pressão intraocular, estão intrinsecamente relacionados ao surgimento e evolução de deformações que podem ter relação direta com o ceratocone.


Subject(s)
Humans , Cornea/pathology , Keratoconus/pathology , Models, Biological , Biomechanical Phenomena , Computer Simulation , Corneal Topography , Cornea/physiopathology , Disease Progression , Elasticity , Finite Element Analysis , Intraocular Pressure , Keratoconus/physiopathology
14.
Arq. bras. oftalmol ; 71(6): 775-780, nov.-dez. 2008. ilus, graf
Article in Portuguese | LILACS | ID: lil-503438

ABSTRACT

OBJETIVOS: Desenvolver um sistema digital, com capacidade de induzir acomodação, para medida do diâmetro e formato da pupila para dez diferentes níveis de iluminação (LUX), variando do nível mesópico ao fotópico. MÉTODOS: Um sistema óptico para conjugar imagens da pupila iluminada por LED infravermelho e branco foi projetado e montado usando um capacete típico de oftalmoscópio e uma máscara típica de mergulhador como suporte e uma câmera CCD de alta resolução e sensibilidade. Algoritmos usando princípios de processamento de imagens foram implementados para leitura do arquivo de vídeo e a detecção automática do centro geométrico e diâmetro da pupila para cada quadro. RESULTADOS: Apresentamos dados preliminares deste sistema para um paciente voluntário. Os dados sobre posição horizontal (x), vertical (y) do centro geométrico e do diâmetro da pupila foram exportados para arquivos texto que podem ser impressos usando um programa convencional de planilha (Excel). O processo de acomodação é garantido por uma mira virtual (LED branco) localizada a 6 metros do olho do paciente e o nível de iluminação é precisamente controlado por uma placa eletrônica que alimenta o LED central que tem sua potência controlada pelo "software". CONCLUSÕES: Com o instrumento desenvolvido dados precisos da posição e tamanhos da pupila podem então ser obtidos estereoscopicamente (para ambas as pupilas e ao mesmo tempo) para qualquer paciente. Acreditamos que tal instrumento possa ser útil em algumas práticas oftálmicas onde as características geométricas da pupila sejam importantes.


PURPOSE: We developed a digital system with accommodation capacities for measurement of the diameter and shape of the in vivo pupil for 10 different levels of illumination intensity, varying from mesopic to photopic. METHODS: An optical system for conjugating images from an infrared and white light illuminated pupil was designed and mounted using an ophthalmoscope helmet and a typical diving mask as support for a high-resolution and sensitivity CCD. Using an IBM compatible computer sequences of video in AVI format were digitized for several seconds at a mean rate of 30 Hz. Algorithms using principles of image processing were implemented for detection of the pupil edges. RESULTS: We present preliminary results of this system for a voluntary patient. Data for the horizontal (x) and vertical (y) central position and for the diameter of the pupil were then exported to files that could be read by typical spread sheet programs (Excel). CONCLUSIONS: In this manner, precise data can be obtained stereoscopically (for both pupils at the same time) for any patient, given that the accommodation process is guaranteed by using a white LED virtual mire located 6 meters from the patient's eye. An electronic board precisely controls the level of illumination. We believe here developed instrument may be useful in certain ophthalmic practices where precise pupil geometric data are needed.


Subject(s)
Adult , Humans , Male , Adaptation, Ocular/physiology , Image Processing, Computer-Assisted/instrumentation , Photic Stimulation/methods , Pupil/physiology , Algorithms , Equipment Design , Fixation, Ocular/physiology , Iris/anatomy & histology , Lighting/methods , Mesopic Vision/physiology , Ophthalmoscopes , Optical Devices , Software
15.
Arq. bras. oftalmol ; 71(6): 831-836, nov.-dez. 2008. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-503449

ABSTRACT

OBJETIVO: Avaliar a diferença da função do músculo levantador da pálpebra superior (FMLPS), distância margem reflexo (DMR1) e altura do sulco palpebral (AS) antes e depois da cirurgia de blefaroplastia superior associada à correção de ptose palpebral. MÉTODOS: Quarenta e quatro pacientes com blefaroptose e dermatocálase foram incluídos. Intervenção: exploração do tendão do músculo levantador da pálpebra superior (MLPS) durante a blefaroplastia, em portadores de blefaroptose e dermatocálase. Nos casos de desinserção, o tendão foi refixado ao tarso. Desfechos analisados: foram analisados de forma bilateral a diferença entre FMLPS, DMR1 e AS antes e depois da intervenção. A dependência entre os olhos foi corrigida por meio de equações de estimativa generalizada. Foi utilizada a correlação de Pearson para quantificar a dependência entre os olhos para FMLPS, DMR1 e AS. RESULTADOS: Houve diferença significante entre as medidas de FMLPS antes e depois da cirurgia, havendo redução da excursão do MLPS após a cirurgia, diminuindo, em média, 1,1 mm (P<0,001). As medidas pré e pós-operatória de DMR1 e AS foram estatisticamente diferentes, sendo que a DMR1 aumentou, em média, 1,6 mm e a AS diminuiu, em média, 3,97 mm (P<0,001) após a cirurgia. Houve correlação significante entre os olhos para todas as variáveis propedêuticas antes e depois da cirurgia. As correlações pré-operatórias foram mais fortes no grupo sem cirurgia prévia. O mesmo foi encontrado para a correlação quanto ao grau de desinserção nos dois olhos (P>0,01). CONCLUSÃO: A função do músculo levantador da pálpebra superior diminui após a cirurgia para a correção da ptose.


PURPOSE: To evaluate the differences between upper eyelid levator muscle function (UELMF), margin reflex distance (MDR1), and eyelid crease height (ECH) before and after ptosis and dermatochalasis surgery. METHODS: Forty-four patients with blepharoptosis and dermatochalasis were enrolled. Intervention: An exploration of the levator tendon (LT) during a blepharoplasty procedure in patients with blepharoptosis and dermatochalasis and in case of its disinsertion, the tendon was reattached to the tarsus. Measured outcome: The differences between UELMF, MDR1, ECH before and after surgery were evaluated bilaterally. Dependency between both eyes was corrected by generalized estimating equations. Pearson correlation was used to evaluate the dependency of the two eyes regarding UELMF, MDR1 and ECH. RESULTS: There was a statistical significant difference between the measures of UELMF before and after surgery with excursion decreasing by a mean value of 1.1 mm after the procedure (P<0.001). Measures of MDR1 showed an increase by a mean of 1.6 mm and ECH decreased by a mean of 3.97 mm (P<0.001). We found a significant correlation between both eyes for all analyzed eyelid variables, both before and after surgery. Correlation before surgery was stronger for the group without previous surgery. The same results for correlation were found for the amount of disinsertion (P>0.001). CONCLUSIONS: Upper eyelid levator muscle function decreases after ptosis surgery.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Blepharoptosis/physiopathology , Eyelids/pathology , Oculomotor Muscles/physiopathology , Blepharoplasty/methods , Blepharoptosis/pathology , Blepharoptosis/surgery , Eyelid Diseases/physiopathology , Eyelid Diseases/surgery , Eyelids/physiopathology , Eyelids/surgery , Oculomotor Muscles/pathology , Oculomotor Muscles/surgery , Treatment Outcome , Tendons/surgery
16.
Arq. bras. oftalmol ; 71(4): 559-563, jul.-ago. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-491889

ABSTRACT

OBJETIVOS: Avaliar a correlação entre as hemorragias peripapilares (HPPs) e a posição do tronco vascular na cabeça do nervo óptico. MÉTODOS: Retinografias de 1.830 pacientes foram revisadas. A posição do tronco vascular retiniano (TVR) foi classificada de acordo com sua localização no hemisfério superior ou inferior e sua posição relativa através da razão entre a distância entre o TVR e o ponto mais inferior do disco óptico e o diâmetro vertical do disco óptico (razão tronco/disco). Pacientes da mesma população, com glaucoma e sem HPPs foram aleatoriamente selecionados para comparação. RESULTADOS: Dos 1.830 pacientes, 46 apresentaram HPPs. Foram detectadas 53 hemorragias em 41 pacientes com glaucoma ou suspeitos de glaucoma, principalmente na região temporal inferior (47,2 por cento). Observou-se concordância negativa entre a localização superior ou inferior do TVR e das HPPs (Kappa= -0,34). Considerando a posição relativa do TVR em relação ao diâmetro vertical do disco óptico (razão tronco/disco), encontramos melhor correlação (valores médios da razão tronco/disco: 0,450-hemorragias superiores e 0,510-hemorragias inferiores; p=0,027). No grupo com HPPs, observamos porcentagem significativamente maior de pacientes com glaucoma de pressão normal (GPN) se comparado ao grupo sem hemorragia (p=0,009). CONCLUSÃO: HPPs foram mais comuns no hemisfério oposto ao da emergência do TVR. Observamos maior prevalência de GPN nos pacientes com hemorragias que nos sem hemorragia.


PURPOSE: To investigate the correlation between optic disc hemorrhages (ODHs) and the position of the central retinal vessel trunk (RVT) in patients with glaucoma. METHODS: Fundus photographs of 1,830 participants were reviewed. The exit position of the central retinal vessel trunk was classified as being in the superior or inferior hemisphere of the optic disc and the relative vertical position was expressed as a fraction of the disc diameter (ratio between the position of the trunk and the diameter of the disk). A group of patients from the same population, but without ODHs, was randomly selected and compared with the patients with ODHs. RESULTS: Among the 1,830 patients, 53 hemorrhages were detected in 41 patients with glaucoma or suspected glaucoma. We found an inverse relationship between the inferior/superior position of the central RVT and the inferior/superior position of the hemorrhages (Kappa= -0.34). Using the trunk/disc ratio, we found that superior ODHs correlated with inferior RVTs (trunk/disc ratio, 0.450; SD=0.070) and inferior ODHs correlated with superior RVTs (trunk/disc ratio, 0.510; SD=0.054) (p=0.027). The number of patients with normal tension glaucoma was significantly higher among patients with ODHs than among those without ODHs (p=0.009). CONCLUSION: Our patients had a negative correlation between the position of central RVT and the location of the ODHs. Normal tension glaucoma was more prevalent among patients with ODHs than among those without it.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Eye Hemorrhage/pathology , Glaucoma/complications , Optic Disk/pathology , Optic Nerve Diseases/pathology , Retinal Vessels/pathology , Brazil/epidemiology , Epidemiologic Methods , Eye Hemorrhage/epidemiology , Fundus Oculi , Intraocular Pressure/physiology , Ocular Hypertension/epidemiology , Ocular Hypertension/pathology , Ocular Hypertension/physiopathology , Optic Nerve Diseases/epidemiology , Photography
17.
Einstein (Säo Paulo) ; 6(4): 473-477, 2008.
Article in Portuguese | LILACS | ID: lil-510098

ABSTRACT

Objetivos: Analisar o programa de Educação Médica Continuada(EMC) desenvolvido no Hospital Israelita Albert Einstein, iniciadoformalmente em 2002, através de seis ciclos sucessivos de 12 meses,com foco de atenção voltado para médicos participantes, quantoà adesão ao programa no decorrer do tempo e quanto à produçãoeducacional medida através de um sistema de créditos. Métodos:Estudo descritivo (populacional) que utilizou um modelo de pontuaçãoatravés de crédito medido por tempo (um crédito = uma hora-aula),baseado em ferramentas educacionais formais e informais, analisandosea adesão do corpo clínico ao programa e o perfil da distribuição decréditos em eventos promovidos pela instituição e fora desta para osparticipantes, para os que cumpriram a meta estabelecida e para umgrupo que participou dos seis ciclos com meta institucional atingida.Para as comparações entre os ciclos, foram utilizadas equações deestimação generalizadas com distribuição Normal (para as médiasde créditos) e Binomial (para as freqüências de médicos com metacumprida). Resultados: Comparando-se os seis ciclos, a adesão docorpo clínico cresceu gradativamente e houve aumento da pontuaçãode créditos no decorrer do tempo (média de créditos crescente). Adistribuição dos créditos segundo o tipo de atividade foi similar aoapresentado na literatura, com maior representação a participação emcongressos, cursos, reuniões científicas e publicações, entre outrasmodalidades educacionais. Conclusões: A análise desse sistema decréditos demonstrou consolidação do programa de EMC no decorrer dotempo com atitude madura e consistente dos participantes.


Subject(s)
/methods , Education, Medical , Education, Medical, Continuing , Hospitals, General
18.
Rev. bras. oftalmol ; 66(5): 327-331, set.-out. 2007. tab, graf
Article in Portuguese | LILACS | ID: lil-481151

ABSTRACT

OBJETIVO: Identificação das principais variáveis que interferem na qualidade de instilação correta de colírio antiglaucomatoso. MÉTODOS: Realizou-se estudo transversal em 40 pacientes glaucomatosos sob tratamento clínico com uso de colírio, aplicando-se um questionário e realizando-se observações quanto à instilação. Foram investigadas as seguintes variáveis: sexo; escolaridade; idade; condições sócioeconômicas; lavagem das mãos; número de gotas por aplicação; alteração motora; pessoa que aplica o colírio; local da aplicação; contato do frasco com as pálpebras, a conjuntiva e a córnea; instrução pregressa; posição de aplicação; ardor, dor ou irritação ocular após a aplicação e acuidade visual. A partir do questionário e das observações, as variáveis citadas foram correlacionadas com a qualidade de instilação. O modelo de análise foi a regressão logística binária. RESULTADOS: Dentre todas as variáveis em questão, apenas a pessoa que aplica o colírio e a sensação de ardor, dor ou irritação ocular mostraram-se estatisticamente significativas para uma adequada instilação de colírio. CONCLUSÃO: A presença de um acompanhante e o ardor à instilação do colírio influenciaram significativamente na qualidade de instilação do mesmo.


PURPOSE:To identify the most important variables interfering with the correct topical administration of antiglaucomatous drugs. METHODS: Forty glaucomatous patients under clinical treatment were interviewed and observed while applying antiglaucomatous drugs. The following variables were analyzed: sex; age; income; washing of the hands; number of drops; motor abnormalities; availability of another person to apply the drug; place of the globe reached; bottle-eye contact; previous instruction; positioning for application; development of a burning sensation, pain or irritation. Using the questionary, the variables were correlated with the quality of instillation. RESULTS: Among all variables, only the availability of another person to apply the drug and the existence of a burning sensation, pain or eye irritation showed statistically important correlation to proper instillation. CONCLUSION: The presence of a companion and the development of burning sensation affected the quality of instillation.

19.
Arq. bras. cardiol ; 89(1): 60-63, jul. 2007. tab
Article in Portuguese | LILACS | ID: lil-459817

ABSTRACT

O ecocardiograma sob estresse com dobutamina é um método bem estabelecido para avaliar doença arterial coronária, cuja sensibilidade tem sido potencializada pela adição de atropina no final do protocolo. Indivíduos com glaucoma, doença com alta prevalência em pacientes cardiopatas com mais de 40 anos, não podem se beneficiar do uso de atropina por ser contra-indicada neste grupo. Além disso, estes indivíduos são tratados freqüentemente com betabloqueadores tópicos (colírios), que podem exercer efeitos sistêmicos diminuindo a freqüência cardíaca, pressão arterial e capacidade pulmonar. O objetivo do nosso trabalho foi verificar se a ocorrência de um possível efeito sistêmico causado por estes colírios, causando baixa resposta cronotrópica, poderia determinar resultados inconclusivos no ecocardiograma sob estresse pela dobutamina nestes pacientes com glaucoma.


Dobutamine stress echocardiography is a well-established method to assess coronary artery disease, of which sensitivity has been enhanced by adding atropine at the end of the protocol. Individuals with glaucoma, a disease with a high prevalence in patients with cardiac diseases older than 40 years, cannot benefit from the use of atropine as it is contraindicated for this group of patients. Additionally, these individuals are often treated with topical betablockers (eye drops), which can have systemic effects by decreasing cardiac frequency, blood pressure and pulmonary capacity. The aim of our study was to verify whether a possible systemic effect caused by the use of these eye drops, yielding a low chronotropic response, could result in inconclusive dobutamine stress echocardiography in patients with glaucoma.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Cardiotonic Agents , Dobutamine , Echocardiography, Stress , Glaucoma/drug therapy , Ophthalmic Solutions/therapeutic use , Analysis of Variance , Blood Pressure/drug effects , Case-Control Studies , Chi-Square Distribution , Cardiotonic Agents/administration & dosage , Cardiotonic Agents/adverse effects , Coronary Disease , Dose-Response Relationship, Drug , Dobutamine/administration & dosage , Dobutamine/adverse effects , Heart Rate/drug effects , Rest
20.
Arq. bras. oftalmol ; 70(2): 312-316, mar.-abr. 2007. tab
Article in Portuguese | LILACS | ID: lil-453174

ABSTRACT

OBJETIVO: Avaliar aspectos demográficos e clínicos de pacientes com conjuntivite alérgica atendidos em centro de referência. MÉTODOS: Estudo prospectivo no qual sinais e sintomas foram graduados com fichas padronizadas e diagnóstico diferencial feito pelo quadro clínico. RESULTADOS: Foram avaliados 207 pacientes, 131 (63,28 por cento) do sexo masculino e com idade variando de 1 a 45 anos. Destes, 38,65 por cento foram diagnosticados como ceratoconjuntivite primaveril; 38,65 por cento como ceratoconjuntivite atópica; 12,56 por cento como conjuntivite alérgica perene e em 10,14 por cento dos pacientes não houve diagnóstico definido. A presença de alergia extra-ocular foi maior em pacientes com conjuntivite atópica (91,25 por cento) e menor em pacientes com primaveril (32,5 por cento) e a história de alergia na família foi maior naqueles sem diagnóstico definido (59,1 por cento) e menor no grupo de conjuntivite primaveril (28,75 por cento). Os sintomas mais intensos foram prurido e lacrimejamento em pacientes com ceratoconjuntivites e houve correlação positiva entre a intensidade dos sintomas e dos sinais clínicos. CONCLUSÕES: Houve predomínio de formas crônicas e graves da alergia ocular com ameaça potencial à função visual.


BACKGROUND: To evaluate demographic and clinical features of patients with allergic conjunctivitis in a reference center. METHODS: Prospective study using sings and symptoms graduated by standardized charts for clinical diagnosis. RESULTS: We evaluated 207 patients, age ranging form 1 to 45 years and of whom 131 (63.28 percent) were males. Of the patients, 38.65 percent presented vernal keratoconjunctivitis; 38.65 percent, atopic keratoconjunctivitis; 12.56 percent, perennial allergic conjunctivitis and in 10.14 percent patients the diagnosis was not defined. Extraocular allergy was more frequent in patients with atopic keratoconjunctivitis (91.25 percent) and less frequent in patients with vernal keratoconjunctivitis (32.5 percent). Family history of allergy was more frequent in patients without defined diagnosis (59.1 percent) and less frequent in the vernal group (28.75 percent). The most itense symptoms were itching and tearing in patients with keratoconjunctivitis. There was a positive correlation between symptom intensity and signs severity. CONCLUSION: Chronic and severe types of ocular allergy, with potential threat to visual function, predominated in the studed group.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Conjunctivitis, Allergic/diagnosis , Conjunctivitis, Allergic/epidemiology , Keratoconjunctivitis/diagnosis , Keratoconjunctivitis/epidemiology , Age Distribution , Asthma/complications , Brazil , Chronic Disease/epidemiology , Conjunctivitis, Allergic/complications , Conjunctivitis, Allergic/etiology , Diagnosis, Differential , Dust , Epidemiologic Methods , Family Health , Genetic Predisposition to Disease , Hot Temperature/adverse effects , Keratoconjunctivitis/complications , Pruritus/etiology , Rhinitis/complications , Seasons , Sex Distribution , Tears , Visual Acuity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL